3 changes: 3 additions & 0 deletions pylabrobot/bmg_labtech/clariostar/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -11,6 +11,7 @@
CLARIOstarDriver,
CLARIOstarFluorescenceResult,
CLARIOstarFluorescenceSpectrumResult,
CLARIOstarLuminescenceResult,
CLARIOstarSimulationDriver,
CLARIOstarStatus,
CLARIOstarZProfileResult,
Expand All @@ -20,6 +21,8 @@
Fluorescence,
FluorescenceConfiguration,
FrameError,
Luminescence,
LuminescenceConfiguration,
MeasurementSettings,
ShakeSettings,
TemperatureController,
Expand Down
8 changes: 7 additions & 1 deletion pylabrobot/bmg_labtech/clariostar/device.py
Original file line number Diff line number Diff line change
Expand Up @@ -10,11 +10,12 @@
from .driver.features.absorbance import Absorbance
from .driver.features.drawer import Drawer
from .driver.features.fluorescence import Fluorescence
from .driver.features.luminescence import Luminescence
from .driver.features.temperature_controller import TemperatureController
from .driver.master import CLARIOstarDriver
from .driver.simulator import CLARIOstarSimulationDriver

# Preliminary: the operating manuals' nominal size, rounded to the cm, the same for the CLARIOstar
# Preliminary: the nominal size, rounded to the cm, the same for the CLARIOstar
# and the CLARIOstar Plus; not yet measured.
SIZE_X = 450.0
SIZE_Y = 510.0
Expand Down Expand Up @@ -189,6 +190,11 @@ def fluorescence(self) -> Optional[Fluorescence]:
"""Fluorescence measurement, or None if the reader has none; known after `setup`."""
return self.driver.fluorescence

@property
def luminescence(self) -> Optional[Luminescence]:
"""Luminescence measurement, or None if the reader has none; known after `setup`."""
return self.driver.luminescence

async def setup(self) -> None:
"""Connect, initialize the reader (about 13 s), and check it is the model this device is.

Expand Down
3 changes: 3 additions & 0 deletions pylabrobot/bmg_labtech/clariostar/driver/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,10 +8,13 @@
CLARIOstarAbsorbanceSpectrumResult,
CLARIOstarFluorescenceResult,
CLARIOstarFluorescenceSpectrumResult,
CLARIOstarLuminescenceResult,
CLARIOstarZProfileResult,
Drawer,
Fluorescence,
FluorescenceConfiguration,
Luminescence,
LuminescenceConfiguration,
MeasurementSettings,
ShakeSettings,
TemperatureController,
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -12,5 +12,10 @@
Fluorescence,
FluorescenceConfiguration,
)
from .luminescence import (
CLARIOstarLuminescenceResult,
Luminescence,
LuminescenceConfiguration,
)
from .measurement import MeasurementSettings, ShakeSettings
from .temperature_controller import TemperatureController
20 changes: 10 additions & 10 deletions pylabrobot/bmg_labtech/clariostar/driver/features/absorbance.py
Original file line number Diff line number Diff line change
Expand Up @@ -76,7 +76,7 @@ class AbsorbanceConfiguration(MeasurementConfiguration):
wavelength_range: Tuple[int, int] = (220, 1000)
"""Wavelengths a read accepts, in nm (the manufacturer's spectrometer range)."""
maximum_wavelengths: int = 8
"""Wavelengths per read (the vendor software manual: up to 8; 8 read on hardware)."""
"""Wavelengths per read (up to 8; 8 read on hardware)."""


# ----------------------------------------
Expand Down Expand Up @@ -155,10 +155,10 @@ def __init__(
# ----------------------------------------

# Water pathlength correction after the wavelength fields, in nm: two wavelengths, a third
# unused, and its bandwidth, as the vendor always sends them.
# unused, and its bandwidth, always sent.
_PATHLENGTH_CORRECTION = (900.0, 993.0, 0.0, 10.0)
# Pause, u16 BE each: when (0 off, 1 before plate reading), then seconds. Off, the vendor sends
# 5 s; on, 5 s captured.
# Pause, u16 BE each: when (0 off, 1 before plate reading), then seconds; off, 5 s are sent,
# and on, 5 s is verified.
_NO_PAUSE = bytes.fromhex("00000005")
_PAUSE_BEFORE_READING = 0x0001

Expand All @@ -177,7 +177,7 @@ def _encode_wavelengths(*nanometres: float) -> bytes:
# Decoding
# ----------------------------------------

# Data reply layout byte [6]: the only one captured, with the temperature controller on or off.
# Data reply layout byte [6]: the only one verified, with the temperature controller on or off.
_DATA_LAYOUT = 0xA9

@staticmethod
Expand All @@ -195,8 +195,8 @@ def _decode_data_reply(self, reply: bytes, wavelengths: List[int]) -> _Decoded:
"""The samples per wavelength and the references, in the reply's well order (row by row), the
wavelengths' calibration pairs and the reference's.

The reply holds n + 3 groups of one u32 per well (the n samples, chromatics 2 and 3, the
reference), then n + 3 calibration pairs, in the same order.
The reply holds n + 3 groups of one u32 per well (the n samples, two groups not decoded,
the reference), then n + 3 calibration pairs, in the same order.

Raises:
ValueError: if the reply is incomplete or not the layout of this read.
Expand Down Expand Up @@ -271,8 +271,8 @@ def _check_arguments(

Raises:
ValueError: listing every violation: not 1 to `maximum_wavelengths` wavelengths, a wavelength
not a whole nm within `wavelength_range`, an unknown report, a matrix well scan (captured
but not decoded), a timeout not positive.
not a whole nm within `wavelength_range`, an unknown report, a matrix well scan (not
decoded), a timeout not positive.
"""
errors = []
maximum = self.configuration.maximum_wavelengths
Expand Down Expand Up @@ -350,7 +350,7 @@ async def measure(
wells: the wells to measure, on the plate; None measures every well.
wavelengths: 1 to `configuration.maximum_wavelengths` wavelengths, each a whole nm within
`configuration.wavelength_range`; all read in one pass.
measurement_settings: how to read; None reads with the defaults (the vendor's).
measurement_settings: how to read; None reads with the defaults.
shake_settings: shake the plate before the read; None does not shake.
report: what the results hold: optical density, or the raw sample counts with the reference
counts and calibration pairs that compute it (`CLARIOstarAbsorbanceResult`).
Expand Down